Water and Air Monitoring and Reporting

Online User Guide: Environmental Monitoring System Web Reporting (EMS WR)

4.3 Graphs


4.3.1 Trend Graph

The Trend Graph allows you to see how the level of a single parameter has changed over time at a single monitoring location. You can choose to graph all historical samples for a parameter, or you can specify a time period.

Trend Graph - Criteria Page

[Graph Disabled]

When you click on the image of the Trend Graph on the main menu, the Trend Graph - Criteria page opens:

Trend Graph - Criteria


top


This table explains page items:

Item Text Item Type Description Notes
main menu button returns you to the Main Menu You will lose any entered criteria
... (multi selection symbol) link — multiple items opens multi selection list related to that field For details, see Multi selection lists
EMS ID field alphanumeric identifier for an EMS monitoring location  
Graphing Y-Axis - Linear radio button instructs EMS WR to produce a Y-axis linear trend graph  
Graphing Y-Axis - Logarithmic radio button instructs EMS WR to produce a Y-axis logarithmic trend graph  
Parameter For Graphing drop-down list restricts graph to this parameter over time  
Time Period - Show The Entire History Of The Selected Parameter radio button graphs all results for the selected parameter default
Time Period - Show The Selected Parameter For A Specific Date Range radio button graphs results for selected parameter for the date period entered  
(Time Period - Date Specified) From field restricts graph to results with a sample collection start date on or after this date Use this field to specify start date when selecting by date range
(Time Period - Date Specified) To field restricts graph to results with a sample collection start date on or before this date Use this field to specify end date when selecting by date range
graph button initiates a search for the selected parameter ensuring that there is at least one result that matches the selection criteria This can take several minutes. Click the graph button only once.

If there are no results that match the selection criteria, EMS WR displays an error message below the menu bar.


top


4.3.2 Exceedance Graph

The Exceedance Graph enables you to determine, at a glance, whether a water sample from a single location complies with the Canadian Drinking Water Guidelines (CDWG).


Exceedance Graph - Criteria Page

When you click on the image of the Exceedance Graph on the main menu, the Exceedance Graph - Criteria page opens:

Exceedance Graph - Criteria

top

This page allows you to select the parameter results you want to graph and produces a graph for those parameter results.

This table explains page items:

Item Text Item Type Description Notes
main menu button returns you to the Main Menu You will lose any entered criteria.
... (multi selection symbol) link — multiple items opens multi selection list related to that field For details, see Multi selection lists
EMS ID field alphanumeric identifier for an EMS monitoring location mandatory
Graph Most Recent Sample radio button restricts sample search to most recent sample associated with monitoring location default
Select A Specific Sample Date radio button restricts sample search to the date you enter in the Sample Date field  
Sample Date field searches based on date specific sample collected The Select A Specific Sample Date radio button must be selected before you can type date information into this field.
(Sample Parameters) Select All link selects all drinking water parameters for graphing default
Sample Parameters) Select Specific Parameter link deselects all sample drinking water parameters After deselecting, you can select specific parameters by clicking on their checkboxes.
(Microbiology) Toggle section checks link toggles between selecting and deselecting all checkboxes in the Microbiology section default is all section checkboxes selected
E Coli check box restricts the graph to include results for e. coli  
Fecal Coliform Bacteria check box restricts graph to results for fecal coliform  
Total Coliform Bacteria check box restricts graph to results for total coliform  
(Physical) Toggle section checks   toggles between selecting and deselecting all checkboxes in the Physical section default is all section checkboxes selected
Conductivity check box restricts graph to results for conductivity  
Total Dissolved Solids Or Residue check box restricts graph to results for total dissolved solids  
Turbidity check box restricts graph to results for turbidity  
(Inorganics) Toggle section checks link toggles between selecting and deselecting all checkboxes in the Inorganics section default is all section checkboxes selected
Chloride Total check box Restricts graph to results for chloride total  
Nitrogen NO3 Total check box restricts graph to results for nitrogen NO3 total  
Sulphate Total check box restricts graph to results for sulfate total  
Cyanide Total check box restricts graph to results for cyanide total  
Ph check box restricts graph to results for pH  
Fluoride Total check box restricts graph to results for fluoride total  
Sodium Total check box restricts graph to results for sodium total  
(Metals) Toggle section checks link toggles between selecting and deselecting all checkboxes in the Metals section Default is all section checkboxes selected
Aluminum Total check box restricts graph to results for aluminum total  
Barium Total check box restricts graph to results for barium total  
Chromium Total check box restricts graph to results for chromium total  
Lead Total check box restricts graph to results for lead total  
Molybdenum Total check box restricts graph to results for molybdenum total  
Zinc Total check box restricts graph to results for zinc total  
Antimony Total check box restricts graph to results for antimony total  
Boron Total check box restricts graph to results for boron total  
Copper Total check box restricts graph to results for copper total  
Manganese Total check box restricts graph to results for manganese total  
Selenium Total check box restricts graph to results for selenium total  
Arsenic Total check box restricts graph to results for arsenic total  
Cadmium Total check box restricts graph to results for cadmium total  
Iron Total check box restricts graph to results for iron total  
Mercury Total check box restricts graph to results for mercury total  
Uranium Total check box restricts graph to results for uranium total  
(Organics) Toggle section checks link toggles between selecting and deselecting all checkboxes in the Organics section default is all section checkboxes selected
Trihalomethanes Total check box restricts graph to results for trihalomethanes total  
graph button initiates a search for the sample ensuring that there is at least one parameter result that matches the selection criteria This can take several minutes. Click the graph button only once.

If there are no parameter results that match the selection criteria, EMS WR will display an error message below the menu bar.


>> Back to Getting Started